• Skip navigation
  • Skip to navigation
  • Skip to the bottom
Simulate organization breadcrumb open Simulate organization breadcrumb close
Friedrich-Alexander-Universität MRT-Forschung am Universitätsklinikum Erlangen
  • FAUTo the central FAU website
  1. Friedrich-Alexander-Universität
  2. Medizinische Fakultät
Suche öffnen
  • Deutsch
  • Campo
  • StudOn
  • FAUdir
  • Jobs
  • Map
  • Help
  1. Friedrich-Alexander-Universität
  2. Medizinische Fakultät
Friedrich-Alexander-Universität MRT-Forschung am Universitätsklinikum Erlangen
Navigation Navigation close
  • MRI Labs
    • sMRI Lab (Hutter)
    • qMRI Lab (Laun)
    • xMRI Lab (Nagel)
    • zMRI Lab (Zaiss)
    • tMRI Lab (Bickelhaupt)
    MRI Labs
  • Team
  • Clinical studies
  • Teaching
  • Publications
  • Directions & Contact
  1. Home
  2. MRI Labs
  3. xMRI Lab (Nagel)

xMRI Lab (Nagel)

In page navigation: MRI Labs
  • tMRI Lab (Bickelhaupt)
  • xMRI Lab (Nagel)
  • zMRI Lab (Zaiss)

xMRI Lab (Nagel)

Contact

Prof. Dr. Armin Nagel

Prof. Dr. Armin Nagel

Professor for metabolic and functional MR imaging

Institute of Radiology

  • Phone number: +49 9131 85-36200
  • Email: armin.nagel@uk-erlangen.de

Links

  • Institute of Radiology - MR-Physics
  • Institute of Radiology
  • Institute of Neuroradiology

News

  • News of AG Nagel

Welcome to the research group Metabolic and Functional MR Imaging!

We always offer exciting Bachelor, Master and PhD topics. If you are interested, please send an email to armin.nagel@uk-erlangen.de.

The research group develops MR measurement techniques for the characterization of metabolic and functional processes. The focus of our research is in the area of ultra-high field (7 Tesla) and so-called X-nucleus MRI. “X” here stands for any atomic nucleus with nuclear spin, except 1H.

1. Imaging of ions (Na+, K+, Cl–)

Sodium (Na+), potassium (K+), and chloride (Cl–) ions play a vital role in many cellular processes such as the excitability of neurons and muscle cells. MRI of these nuclei – often denoted as X-nuclei MRI – is a promising approach to non-invasively examine cell viability.

Over the past decades, 23Na MRI has become a widely used technique to noninvasively determine the total tissue sodium concentration. It is a valuable tool in biomedical research despite its challenges that include low signal-to-noise-ratio (SNR) and fast signal decay [1,2]. Imaging of chloride [3] and potassium [4,5,6] is even more challenging due to the even lower signal intensity, which makes the use of ultra-high field strengths (B0 ≥ 7 T) indispensable.

Figure 1 shows exemplary sodium and potassium concentration maps of healthy lower leg muscle tissue acquired with a dual-tuned 23Na/39K calf coil at 7 T [6]. Figure 2 shows sodium images of a healthy volunteer and a patient with Duchenne muscular dystrophy [7]. Elevated muscular sodium signal intensities were regularly observed in patients with Duchenne muscular dystrophy (DMD) compared with controls, and were present even in absence of fatty degenerative changes and water T2 increases [7]. This Na+ overload might contribute to the disease progression [8]. Thus, 23Na MRI may be considered as a potential marker to characterize dystrophic muscle tissue at an early stage.

X-nuclei MRI / Imaging of ion concentrations

Figure 1: In vivo Na+ and K+ concentration maps of the lower leg of a healthy volunteer acquired with a dual-tuned 23Na/39K calf coil at 7 T.

Figure 2: Fat fraction (FF) maps, water T2 maps, Na+ concentration maps and Na+ inversion recovery images of the lower legs of a healthy control and a patient with Duchenne muscular dystrophy (DMD).

Probing the molecular environment of sodium and potassium ions using  23Na and 39K MRI

One approach to analyze the molecular environment is to examine the existence of multiple quantum coherences (MQC) as they are directly linked to the sodium ions’ molecular environment and the corresponding quadrupolar interactions [9]. MQC describe superpositions between nuclear energy levels with a difference in nuclear quantum number of Δm > 1 that can be induced in a system of nuclei possessing a nuclear spin I ≥ 1. Spin-3/2 nuclei as 23Na and 39K exhibit four nuclear Zeeman levels, therefore double quantum coherences (Δm = 2) and triple quantum coherences (Δm = 3) can be generated. In contrast to single quantum coherences, MQC are not directly MR observable. Instead, so-called multiple quantum filters (MQF) have to be applied to detect them. Triple quantum filtered imaging (TQF) offers the possibility to detect signal of ions located within restricted motional regimes and has been shown to provide weighting towards intracellular space. Double quantum filtered MRI with magic angle excitation (DQF-MA) can be used to selectively detect ions located within anisotropic structures such as muscle fibers. However, all these techniques suffer from low SNR and are prone to magnetic field inhomogeneities [10,11].

In this project, imaging techniques based on multiple quantum filtration are developed and applied both to healthy subjects and patients with muscular pathologies. The aim of this project is to probe the molecular environments (e.g. intra vs. extracellular) of sodium and potassium ions by making use of their quadrupolar interactions.

In Figure 3, a spin density weighted (DW) 23Na image of human lower leg is compared to a triple quantum filtered (TQF) and a double quantum filtered with magic angle excitation (DQF-MA) 23Na image [11].

Probing the molecular environment of Na+ and K+

Figure 3: Spin density weighted (DW) (a), triple quantum filtered (TQF) (b), and double quantum filtered with magic angle excitation (DQF-MA) (c) 23Na images of a the lower leg of a healthy volunteer. The TQF passes only signal from sodium nuclei that are located in a motional restricted environment. The DQF-MA selectively detects signal from sodium nuclei connected to ordered structures.

2. Ultra-High Field (7 Tesla) MRI

One of the main challenges in magnet resonance imaging (MRI) is the limited signal-to-noise ratio (SNR). The University Hospital Erlangen is one of the few sites hosting a clinically approved Ultra High Field 7 Tesla MRI system. The increased field strength compared to conventional systems allows for a greatly improved SNR so that image resolutions of a few 100 micrometers can be reached.

As the wavelength of the transmit field becomes of the same size as the human head at 7 Tesla, one must face the challenge of minimizing the arising inhomogeneous image brightness (Fig. 4, left). Moreover, the electric field may become inhomogeneous potentially entailing hot spots of the specific absorption rate (SAR), which must be taken into account in SAR calculations.

In order to achieve a homogeneous transmit field, we shape the radio frequency (RF) excitation field using eight different transmission coils, which transmit in parallel (parallel Transmit, pTx) [12]. For this, the transmission coils and the gradient coils are driven simultaneously but independently with individual voltage curves and pulse shapes. The basic underlying calculation approach is called ‘Transmit-SENSE’, in analogy to the established ‘SENSE’ algorithm using receive coil sensitivity profiles. During excitation, gradients are applied to influence the static magnetic field using the concept of ‘transmit k-space’. The optimal interaction of k-space trajectory and RF pulse shapes of all transmit coils is expressed as a minimization problem to be solved patient-specifically during an examination and as fast as possible to make it feasible in clinical routine.

Using this approach, images with little brightness inhomogeneity and low SAR exposure can be achieved (Fig. 5, right) [13].

Ultra-high field (7 Tesla) MRI

Figure 4: 7 Tesla ultra-high field MRI system.

Figure 5: MP-RAGE image at 7 Tesla. Left: Image brightness drops in some regions owing to the inhomogeneous transmit field. Right: By using the pTX approach, we were able to homogenize the image brightness.


 

[1] Huhn K, Engelhorn T, Linker RA, Nagel AM.
Potential of Sodium MRI as a Biomarker for Neurodegeneration and Neuroinflammation in Multiple Sclerosis.
Front Neurol 2019; 10(84).

[2] Ladd ME, Bachert P, Meyerspeer M, Moser E, Nagel AM, Norris DG, Schmitter S, Speck O, Straub S, Zaiss M.
Pros and cons of ultra-high-field MRI/MRS for human application.
Prog Nucl Mag Res Sp 2018; 109: 1-50.

[3] Nagel AM, Lehmann-Horn F, Weber MA, Jurkat-Rott K, Wolf MB, Radbruch A, Umathum R, Semmler W.
In vivo 35Cl MR imaging in humans: a feasibility study.
Radiology. 2014 May;271(2):585-95.

[4] Umathum R, Rösler MB, Nagel AM.
In vivo 39K MR imaging of human muscle and brain.
Radiology. 2013 Nov;269(2):569-76.

[5] Nagel AM, Umathum R, Rösler MB, Ladd ME, Litvak I, Gor’kov PL, Brey WW, Schepkin VD.
39K and 23Na relaxation times and MRI of rat head at 21.1 T.
NMR Biomed. 2016 Jun;29(6):759-66.

[6] Gast LV, Mueller M, Hensel B, Uder M, Nagel AM.
Combined 23Na/39K MRI for the quantification of Na+ and K+ concentrations in human skeletal muscle at 7 T.
Proc Intl Soc Mag Reson Med 27 2019.

[7] Gerhalter T, Gast LV, Marty B, Martin J, Trollmann R, Schussler S, Roemer F, Laun FB, Uder M, Schroder R, Carlier PG, Nagel AM.
23Na MRI Depicts Early Changes in Ion Homeostasis in Skeletal Muscle Tissue of Patients With Duchenne Muscular Dystrophy.
J Magn Reson Imaging 2019; https://doi.org/10.1002/jmri.26681

[8] Lehmann-Horn F, Weber MA, Nagel AM, Meinck HM, Breitenbach S, Scharrer J, Jurkat-Rott K.
Rationale for treating oedema in Duchenne muscular dystrophy with eplerenone.
Acta Myol 2012; 31(1): 31-39.

[9] Navon G, Shinar H, Eliav U, Seo Y.
Multiquantum filters and order in tissues.
NMR Biomed. 2001;14(2):112-132.

[10] Matthies C, Nagel AM, Schad LR, Bachert P.
Reduction of B(0) inhomogeneity effects in triple-quantum-filtered sodium imaging.
J Magn Reson. 2010;202(2):239-244.

[11] Gast LV, Gerhalter T, Hensel B, Uder M, Nagel AM.
Double quantum filtered 23Na MRI with magic angle excitation of human skeletal muscle in the presence of B0 and B1 inhomogeneities.
NMR Biomed. 2018; e4010.

[12] Ladd ME, Bachert P, Meyerspeer M, Moser E, Nagel AM, Norris DG, Schmitter S, Speck O, Straub S, Zaiss M.
Pros and cons of ultra-high-field MRI/MRS for human application.
Prog Nucl Mag Res Sp 2018; 109: 1-50.

[13] Herrler J, Liebig P, Gumbrecht R, Ritter D, Schmitter S, Maier A, Schmidt M, Uder M, Doerfler A, Nagel AM.
Fast online-customized (FOCUS) parallel transmission pulses: A combination of universal pulses and individual optimization.
Magn Reson Med 2021;85(6):3140-3153.

Alle News der AG Nagel

New paper: Feasibility of 7T 39K/23Na Magnetic Resonance Imaging for assessing muscular ion balance in hypokalemic periodic paralysis

Zum Artikel "New paper: Feasibility of 7T 39K/23Na Magnetic Resonance Imaging for assessing muscular ion balance in hypokalemic periodic paralysis"

Congratulations to Claudius Sebastian Mathy and co-authors on the recently published article "Feasibility of 7T 39K/23Na Magnetic Resonance Imaging for assessing muscular ion balance in hypokalemic periodic paralysis"! This study used combined potassium-39 and sodium-23 MRI at 7 Tesla to investig...

25. April 2025 Category: AG Nagel, Allgemein, Startseite
Continue

New paper: Longitudinal Follow-Up of Patients With DuchenneMuscular Dystrophy Using Quantitative 23Na and 1H MRI

Zum Artikel "New paper: Longitudinal Follow-Up of Patients With DuchenneMuscular Dystrophy Using Quantitative 23Na and 1H MRI"

Congratulations to Dr. rer. nat. Teresa Gerhalter and co-authors on the recently published article "Longitudinal Follow-Up of Patients With DuchenneMuscular Dystrophy Using Quantitative 23Na and 1H MRI"! This longitudinal MRI study in boys with Duchenne muscular dystrophy (DMD) found that sodium ...

25. April 2025 Category: AG Nagel, Allgemein, Startseite
Continue

New paper: Interleaved 23Na/1H MRI of the human heart at 7 T using a combined 23Na/1H coil setup and 1H parallel transmission

Zum Artikel "New paper: Interleaved 23Na/1H MRI of the human heart at 7 T using a combined 23Na/1H coil setup and 1H parallel transmission"

Congratulations to Laurent Ruck and co-authors on the recently published article ‘Interleaved 23Na/1H MRI of the human heart at 7 T using a combined 23Na/1H coil setup and 1H parallel transmission’! This study investigated the application of interleaved 23Na/1H MRI at 7 T using parallel excitatio...

12. March 2025 Category: AG Nagel, Allgemein, Startseite
Continue

Report on xMRI lab in FAU magazine

Zum Artikel "Report on xMRI lab in FAU magazine"

In November 2024, a report on X-MRI was published in the FAU magazine. The article can be accessed via the following link: Taking images with a grain of salt | FAU Erlangen-Nürnberg  

26. February 2025 Category: AG Nagel
Continue

Proposal for 14 Tesla MRI system submitted …

Zum Artikel "Proposal for 14 Tesla MRI system submitted …"

On the road toward implementing a 14 Tesla human whole-body system in Germany, we responded to a call in 2024 from the German Federal Ministry of Education and Research (Bundesministerium für Bildung und Forschung, BMBF) to submit projects to develop new national scientific infrastructures: https://...

26. February 2025 Category: AG Nagel, Allgemein, Startseite
Continue

New paper: Determination of Tissue Potassium and Sodium Concentrations in Dystrophic Skeletal Muscle Tissue Using Combined Potassium (39K) and Sodium (23Na) MRI at 7T

Zum Artikel "New paper: Determination of Tissue Potassium and Sodium Concentrations in Dystrophic Skeletal Muscle Tissue Using Combined Potassium (39K) and Sodium (23Na) MRI at 7T"

Congratulations to Dr. Lena Gast and co-authors on the recently published article "Determination of Tissue Potassium and Sodium Concentrations in Dystrophic Skeletal Muscle Tissue Using Combined Potassium (39K) and Sodium (23Na) MRI at 7T"! This study used combined 23Na/39K MRI at 7T to assess ap...

18. February 2025 Category: AG Nagel, Allgemein, Startseite
Continue

New paper: Accelerated B1+ mapping and robust parallel transmit pulse design for heart and prostate imaging at 7T

Zum Artikel "New paper: Accelerated B1+ mapping and robust parallel transmit pulse design for heart and prostate imaging at 7T"

Congratulations to Nico Egger and co-authors on the recently published article "Accelerated B1+ mapping and robust parallel transmit pulse design for heart and prostate imaging at 7T"! In this publication, the performance of universal parallel transmit (pTx) pulses for prostate and heart imaging ...

19. June 2024 Category: AG Nagel, Allgemein, Startseite
Continue

New Paper: Fast online spectral-spatial pulse design for subject-specific fat saturation in cervical spine and foot imaging at 1.5 T

Zum Artikel "New Paper: Fast online spectral-spatial pulse design for subject-specific fat saturation in cervical spine and foot imaging at 1.5 T"

Congratulations to Christian Eisen (and colleagues) on the recently published paper "Fast online spectral-spatial pulse design for subject-specific fat saturation in cervical spine and foot imaging at 1.5 T"! A new fat saturation method for MRI is presented, which aims to ensure a more reliable a...

17. February 2024 Category: AG Nagel, Allgemein, Startseite
Continue

New paper: Multi-echo–based fat artifact correction for CEST MRI at 7 T

Zum Artikel "New paper: Multi-echo–based fat artifact correction for CEST MRI at 7 T"

Congratulations to Katharina Tkotz! The paper "Multi-echo–based fat artifact correction for CEST MRI at 7 T“ by Katharina Tkotz et al. was recently accepted for publication by Magnetic Resonance in Medicine and is now available online. https://onlinelibrary.wiley.com/doi/10.1002/mrm.29863

29. September 2023 Category: AG Nagel, Allgemein, Startseite
Continue

New DFG Research Group: “Fast mapping of quantitative and metabolic MRI-fingerprints in ultra-high magnetic field”

Zum Artikel "New DFG Research Group: “Fast mapping of quantitative and metabolic MRI-fingerprints in ultra-high magnetic field”"

The MR physics research groups led by Prof. Armin Nagel, Prof. Frederik Laun and Prof. Moritz Zaiss are funded within a research group by the German Research Foundation (DFG) for the next 4 years! The goal is to develop a "magnetic resonance biosignature" at 7 Tesla that will provide information bey...

28. June 2023 Category: AG Laun, AG Nagel, AG Zaiss, Allgemein, Startseite
Continue
Friedrich-Alexander-Universität
Erlangen-Nürnberg

Schlossplatz 4
91054 Erlangen
  • Legal notice
  • Privacy
  • Accessibility
  • Facebook
  • RSS Feed
  • Twitter
  • Xing
Up